Product Description:

Tsingcarbo® 300 Thermal Desorption Tube is a high-performance three-bed adsorbent tube designed for sampling and thermal desorption analysis of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in air, water, soil, and industrial process emissions. It is engineered with proprietary carbon-based adsorbents from Suzhou Tsingcarbo Nano, offering superior trapping efficiency, thermal stability, and desorption completeness for a broad spectrum of C2 and higher molecular weight organic compounds. This tube complies with international standard methods (e.g., US EPA TO-1, TO-2, TO-3, TO-17) and is compatible with mainstream thermal desorption instruments, making it an ideal choice for environmental monitoring, workplace safety assessment, and industrial quality control.


1. Adsorbent Composition

Tsingcarbo® 300 Tube is packed with three layers of Tsingcarbo proprietary adsorbents, optimized for sequential trapping of volatile to semi-volatile compounds:

Tsingcarbo C (Graphitized Carbon Black)High-surface-area graphitized carbon black, designed for trapping medium-to-high boiling point VOCs (C₅–C₂₀), with excellent thermal stability and low bleed.

Tsingcarbo B (Graphitized Carbon Black)Medium-surface-area graphitized carbon black, targets medium volatility compounds (C₅–C₁₂), provides strong retention and easy desorption.

Tsingcarbo S (Carbon Molecular Sieve)Microporous carbon molecular sieve, efficiently traps highly volatile compounds (C₂–C₅), ensuring no breakthrough during sampling.

Bed ConfigurationTsingcarbo C (front) → Tsingcarbo B (middle) → Tsingcarbo S (rear), separated by inert quartz wool to prevent adsorbent mixing and ensure uniform gas flow.


2. Physical Specifications

Parameter

Details

Tube Material

316 Stainless Steel / Borosilicate Glass (optional)

Dimensions

O.D. × I.D. × Length: 1/4 in. × 3.5 in. (6 mm × 4 mm × 89 mm)

Adsorbent Bed Length

Standard multi-bed configuration (total ~100–150 mg adsorbent)

End Caps

Brass / Stainless Steel Swagelok-style caps (sealed for contamination prevention)

Preconditioning

Factory preconditioned at high temperature under inert gas flow, ready for immediate use

Packaging

10 tubes per package


3. Key Features & Advantages

Proprietary Adsorbent TechnologyUtilizes Tsingcarbo C/B/S tailored Carbon Adsorbents, delivering higher trapping capacity and lower background interference than conventional carbon materials.

Broad Analyte CoverageCaptures C₂–C₂₀ volatile and semi-volatile organic compounds, covering alkanes, aromatics, halocarbons, oxygenates, and more.

Excellent Thermal StabilityWithstands high desorption temperatures (up to 350°C), enabling complete release of adsorbed compounds and reducing carry-over.

Low Bleed & High PurityStrict quality control ensures minimal column bleed, improving GC/MS detection sensitivity and data accuracy.

Instrument CompatibilityFully compatible with thermal desorption systems from PerkinElmer, Markes, DANI, OI Analytical, Shimadzu, Gerstel, and other brands.

Compliance with StandardsMeets requirements of US EPA TO-1, TO-2, TO-3, TO-17, NIOSH, and Chinese environmental monitoring standards (e.g., HJ 644, HJ 734).

Reusable & Cost-EffectiveCan be reconditioned multiple times (20–50 uses) under proper conditions, reducing operational costs.


4. Applications

Environmental Air MonitoringAmbient air VOCs, indoor air quality (IAQ), and fugitive emission testing.

Workplace SafetyIndustrial hygiene and occupational exposure assessment for volatile chemicals.

Soil & Water AnalysisVolatile compounds in soil, groundwater, and aqueous samples.

Consumer Products TestingVOC emissions from furniture, building materials, electronics, and cosmetics.

Industrial Process ControlEmission monitoring in petrochemical, pharmaceutical, printing, and coating industries.

Forensic & ResearchTrace-level VOC analysis in forensic science and environmental research.


5. Performance Parameters

Breakthrough Volume≥ 100 L for C₂–C₅ compounds under standard sampling conditions.

Desorption Efficiency≥ 95% for target analytes at recommended desorption temperatures.

Background ContaminationBlank levels meet EPA and ISO requirements for trace analysis.

Pressure DropLow and consistent pressure drop, compatible with standard air sampling pumps.


6. Recommended Operating Conditions

Sampling Flow Rate0.1–1.0 L/min (adjust based on analyte volatility and sampling duration).

Sampling Volume1–100 L (depending on analyte concentration and breakthrough limits).

Thermal Desorption Temperature250–350°C (optimize for specific analytes).

Desorption Time5–15 minutes.

Carrier GasHigh-purity nitrogen or helium (99.999%+).


7. Storage & Handling

Store tubes in a clean, dry, and cool environment (temperature: 0–25°C, humidity < 60%).

Keep tubes sealed with end caps when not in use to prevent contamination and adsorbent degradation.

Avoid exposure to organic solvents, high humidity, and direct sunlight.

Recondition used tubes at 320–350°C under inert gas flow for 1–2 hours before reuse.


8. Quality Assurance

Each Tsingcarbo® 300 Thermal Desorption Tube undergoes rigorous factory testing, including:

Adsorbent uniformity and packing verification.

Preconditioning validation to ensure low background.

Leak testing and pressure drop measurement.